Secretion clearance
Nurses
Consider oral suctioning if needed
- Use Yankauer suction tube
- Suction levels for adults are 100-150 mmHg on wall suction and 10-15 mmHg on portable suction units
- Only suction what you can see
Consider a referral to physiotherapy
- They can offer chest clearance exercises
- They can perform deep suctioning if it is required